Precautions for Using the Autoclave Machine

Ⅰ. Learn about the autoclave machine


The autoclave is a kind of equipment that uses high pressure and steam for sterilization and disinfection. It is widely used in medical, scientific research, catering, agriculture, biology and other industries. The autoclave is equipped with an electric lock system, which makes it easier to safely open the lid when touching the controller. The application of the safety two-way detection interlock device greatly ensures the safety of the equipment. In recent years, the design and application of high-pressure sterilizers have been greatly improved, so they are also welcomed by enterprises. The autoclave is mainly used in medical and health undertakings, national scientific research, biology, agriculture and other units to disinfect and sterilize medical equipment, dressings, glassware, solution cultures, etc.


Ⅱ. Precautions for using the autoclave machine


1. Preliminary treatment of disinfected items. As long as it is medical equipment, sheets and clothing that have been exposed to pathogenic microorganisms, they need to be disinfected with chemical disinfectants. Then clean them in accordance with conventional methods, especially the various items used in some infectious wards, to avoid re-contamination;


2. Use suitable packaging and containers for disinfected items, generally white cotton double-layer cloth bags. You should not use the item packaging after washing, and do not use the string to tie it too loose or too tight. When using a container for storage, choose a container that can block the intrusion of external microorganisms and has better steam penetration. In this way, the effect of disinfection and sterilization in the process of using the autoclave digital will be better;


3. In the process of using the autoclave, the air must be removed cleanly. If there is air in the pot, the pressure pointed by the air pressure needle is not the pressure generated by saturated steam, which will affect the sterilization effect of the autoclave, especially for the table top autoclave sterilizer;


4. Calculate the sterilization time strictly and reasonably. Sterilization time generally includes penetration time, maintenance time, and safety time. According to these three points, the user can operate according to the actual situation during use.


Hot Scientific Instrument Recommendation

Products
Contact Zonkia

Welcome your presence! You can send us an email to know more about our medical laboratory equipments. We will get in touch with you within 24 hours.

Tel/WhatsApp +86 13485601308
Add No 666 Innovation Avenue, High-tech zone, Hefei city, Anhui Province, China
No 666 Innovation Avenue, High-tech zone, Hefei city, Anhui Province, China
zonkia@ustczonkia.com
+86 13485601308